1. Insert the valve air inlet into the cylinder angle valve interface, and turn the handwheel counterclockwise. The pressure reducing valve should be kept in a horizontal position, the gas pipe must be inserted into the cordon, and the gas outlet hose should be fixed with a clamp.
2. The outlet air flow and pressure have been adjusted before the product leaves the factory. Do not adjust without authorization.
3. The angle valve of the cylinder should be closed after the product is used, so that the pressure reducing valve is not in working condition.
4. For the convenience of operation and maintenance, the valve is generally installed upright on a horizontal pipeline.